Description
Cast steel lid and a surrounding cast steel support frame, which is supported around its perimeter on the side walls of the pit.
- CO = 423 mm
- Test block = 240 mm x 240 mm (square)
- Applied serviceability load: 600 kN
- Max. permanent set: 0.14 mm (permissible 1 mm)
- Max. deflection: 6.3 mm (permissible 9.6 mm)
- Applied ultimate limit state load: 900 kN
- No visible damage
- Passed test
Building Code and Standards
AS 3996-2006
Report holder details
J&D McLennan Ltd
warehouse
PO Box 30087, Lower Hutt, New Zealand