System Number: BK106
Description: For their successful use, texture-coated claddings - typically stucco, EIFS (exterior insulation and finishing system) or texture-coated flush-stopped fibre-cement - rely on good detailing and installation, a cavity, a coating to seal the surface against moisture penetration and regular maintenance of that coating to ensure the surface remains weatherproof. From 2005, a cavity became a requirement for stucco and EIFS or texture-coated fibre-cement where the building weathertightness risk exceeds 6; from 2011, a cavity became a requirement for all EIFS and flush-finished fibre-cement.