Skip to main content

Appraisal number: 862 (2019)

Date issued: 13 Aug 2019

Kirin Insulated Panel System - External Façades and Roofs

Description

The Kirin Insulated Panel System is for use as single skin external wall façades and roofs. The system incorporates Kirin Insulated Panels, which are sandwich panels fabricated by injecting polyisocyanurate (PIR) foam between coil-coated steel or stainless steel faces.

The Kirin Insulated Panels come in thicknesses ranging from 50 to 200 mm, widths of 1000 mm and lengths of up to 11.85 m. Several different options are available for the exposed surface finish of the steel, including both profile and colour.

Scope

The Kirin Insulated Panel System has been appraised for use as a non-loadbearing external façade and roof system for buildings within the following scope:

  • On class 5, 6, 7, 8, 9a and 9b buildings.
  • Constructed with concrete framing complying with AS 3600 and/or steel framing complying with AS 4100.
  • Subjected to maximum wind pressures for weathertightness design of 2.15 kPa ultimate limit state (ULS).

The Kirin Insulated Panel System has not been assessed for use where fire rated walls are required.

The structural, weatherproofing and thermal design of the Kirin Insulated Panel System for each specific structure is the responsibility of the building designer.

The installation of the Kirin Insulated Panel System is to be carried out by installers trained by Kirin Insulated Panels New Zealand Ltd.

Technical literature

  • IB-CO701 Insulated Building Corner Detail, 23 July 2014
  • IB-CO702 Insulated Building Corner Detail, 23 July 2014
  • IB-CO703 Insulated Building Corner Detail, 23 July 2014
  • IB-CO704, Insulated Building Corner Detail, 23 July 2014
  • IB-CO705 Insulated Building Corner Detail, 23 July 2014
  • IB-EWB708 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB709 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB710 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB711 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB712 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB713 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB714 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-EWB715 Insulated Building External Wall Base Detail 23 July 2014
  • IB-EWB716 Insulated Building External Wall Base Detail, 23 July 2014
  • IB-PJ720 Insulated Building External Panel Joint Detail, 23 July 2014
  • IB-PJ721 Insulated Building External Panel Joint Detail, 23 July 2014
  • IB-WS724 Insulated Building Wall Support Detail, 23 July 2014
  • R-BF701 Roofing Barge & Fascia Flashing Detail, 23 July 2014
  • R-BF702 Roofing Barge & Fascia Flashing Detail, 23 July 2014
  • R-BF703 Roofing Barge & Fascia Flashing Detail, 23 July 2014
  • R-GF704 Roofing Gable Flashing Detail, 23 July 2014
  • R-PF707 Roofing Parapet Flashing Detail, 23 July 2014
  • R-PF708 Roofing Parapet Flashing Detail, 23 July 2014
  • R-PF709 Roofing Parapet Flashing Detail, 23 July 2014
  • R-PF712 Roofing Parapet Flashing Detail, 23 July 2014
  • R-PG714 Roofing Parapet & Gutter Detail, 23 July 2014
  • R-PG715 Roofing Parapet & Gutter Detail, 23 July 2014
  • R-PG716 Roofing Parapet & Gutter Detail, 23 July 2014
  • R-RF717 Roofing Ridge Flashing Detail, 23 July 2014
  • R-RF718 Roofing Roof lap joint detail, 23 July 2014
  • R-RL719 Roofing Roof Lap Joint Detail, 23 July 2014
  • R-RL720 Roofing Roof Lap Joint Detail, 23 July 2014
  • R-VG721 Roofing Valley Gutter Detail, 23 July 2014

Consenting instructions

Always refer to the Appraisal in full and the technical literature.

Appraisal holder

Kirin Insulated Panels New Zealand Ltd
Address:
Phone: (09) 950 6768

Marketer details

Address:
Phone:
Web:
Email: